Installation

Inverter Detail

Uncover in-depth details about your primary inverter, essential for understanding your system's performance. The information is categorized as follows:

Inverter Info

  • Serial Number: Unique identifier for the master inverter.
  • Model: Model information of the inverter.
  • Device Name: Assigned name of the inverter device.
  • Firmware Version: Version of the firmware installed on the inverter.
  • Connection Date: Date when the inverter connected to the RCT Power Portal.
  • Last Contact: Date and time of the last data storage in the database.
  • AC Rated Output: Rated output power of the inverter.

Current Values

  • AC Power: Current AC power generated.
  • External Power: Power from external sources.
  • Battery Power: Power from the battery (displayed for master-slave systems only).
  • Max Allowed Grid Feed-In: Maximum allowed grid feed-in.
  • Heat Sink Temperature 1: Temperature of heat sink 1.
  • Heat Sink Temperature 2: Temperature of heat sink 2.

Battery Info

Only for master-slave systems, the battery information is integrated into the inverter detail section, providing crucial details about the battery's status:

  • BMS Serial Number: Battery Management System serial number.
  • Model: Model information of the battery.
  • Software Version: Version of the software installed on the BMS.
  • SOC: State of Charge of the battery.

Battery Detail

Explore a comprehensive overview of your battery's performance and status, organized into two configurations:

Single Battery

Battery Info

  • BMS Serial Number: Battery Management System serial number.
  • Model: Model information of the battery.
  • BMS Software Version: Version of the software installed on the BMS.
  • Battery Installed Capacity: Installed capacity of the battery.
  • SOC: State of Charge of the battery.

Current Power

  • Power: Current power generated by the battery.

Active Current

  • Charge - Max: Maximum charge current.
  • Discharge - Max: Maximum discharge current.

Double Tower

Battery Info

  • Battery Installed Capacity: Total installed capacity is the sum of both towers.
  • SOC: Total system State of Charge.
Tower 1
  • BMS Serial Number: Battery Management System serial number specific to Tower 1.
  • Model: Model information of the battery.
  • BMS Software Version: Version of the software installed on the BMS in Tower 1.
  • Battery Installed Capacity: Installed capacity for Tower 1.
  • SOC: State of Charge of Tower 1.
Tower 2
  • BMS Serial Number: Battery Management System serial number specific to Tower 2.
  • Model: Model information of the battery.
  • BMS Software Version: Version of the software installed on the BMS in Tower 2.
  • Battery Installed Capacity: Installed capacity for Tower 2.
  • SOC: State of Charge of Tower 2.

Slave Inverter Detail (For Master-Slave Systems)

Detailed information about each slave inverter is displayed in a dedicated section. The battery slave information is now found in the Slave Inverter section, providing insights into the performance and status of each slave inverter:

Inverter Info

  • Serial Number: Unique identifier for the slave inverter.
  • Model: Model information of the slave inverter.
  • Device Name: Assigned name of the slave inverter device.
  • Version: Version information of the slave inverter.

Current Values

  • AC Power: Current AC power generated by the slave inverter.
  • Battery Power: Power from the battery (for slave inverters with a battery only).

Battery Info

For slave inverters connected to a battery, additional information is displayed in the Slave Inverter section:

  • Software Version: Version of the software installed on the slave battery.
  • SOC: State of Charge of the slave battery.